activity against multi drug resistant e coli strain atcc baa Search Results


99
ATCC multi drug resistant e coli
Multi Drug Resistant E Coli, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Escherichia+coli+(Migula)+Castellani+and+Chalmers/10__1071_slash_ma23019-734-24-28
Average 99 stars, based on 1 article reviews
multi drug resistant e coli - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

94
ATCC activity against multi drug resistant e coli strain atcc baa
Activity Against Multi Drug Resistant E Coli Strain Atcc Baa, supplied by ATCC, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Escherichia+coli/10__1071_slash_mav43n4-726-8-15
Average 94 stars, based on 1 article reviews
activity against multi drug resistant e coli strain atcc baa - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

95
ATCC multi drug resistant e coli atcc baa 2471
Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) <t>E.</t> <t>coli</t> and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).
Multi Drug Resistant E Coli Atcc Baa 2471, supplied by ATCC, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Escherichia+coli%3B+Strain+1100101/pm33747737-106-9-13
Average 95 stars, based on 1 article reviews
multi drug resistant e coli atcc baa 2471 - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

90
Cubist Pharmaceuticals multi-drug resistant e. coli strain
Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) <t>E.</t> <t>coli</t> and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).
Multi Drug Resistant E. Coli Strain, supplied by Cubist Pharmaceuticals, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/multi+drug+resistant+e++coli+strain/pm20606699-64-4-0
Average 90 stars, based on 1 article reviews
multi-drug resistant e. coli strain - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

96
ATCC multi drug resistant e coli atcc baa 2469
Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) <t>E.</t> <t>coli</t> and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).
Multi Drug Resistant E Coli Atcc Baa 2469, supplied by ATCC, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Akkermansia+ignis%3B+Strain%3A+MmAkk3/pm37405270-60-56-60
Average 96 stars, based on 1 article reviews
multi drug resistant e coli atcc baa 2469 - by Bioz Stars, 2026-10
96/100 stars
  Buy from Supplier

93
ATCC multi drug resistant e coli sms 3 4
Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) <t>E.</t> <t>coli</t> and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).
Multi Drug Resistant E Coli Sms 3 4, supplied by ATCC, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Escherichia+coli+(Migula)+Castellani+and+Chalmers/us09920058-815-18-23
Average 93 stars, based on 1 article reviews
multi drug resistant e coli sms 3 4 - by Bioz Stars, 2026-10
93/100 stars
  Buy from Supplier

95
ATCC multi drug resistant e faecium
Comparison between the decontamination effectiveness of UVC LEDs and chemical methods.
Multi Drug Resistant E Faecium, supplied by ATCC, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Enterococcus+faecium%3B+Strain+MMC4/pmc09028096-63-12-15
Average 95 stars, based on 1 article reviews
multi drug resistant e faecium - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

99
ATCC multi resistant e coli atcc 25922
Comparison between the decontamination effectiveness of UVC LEDs and chemical methods.
Multi Resistant E Coli Atcc 25922, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Escherichia+coli/10__3390_slash_ddc3030034-103-29-32
Average 99 stars, based on 1 article reviews
multi resistant e coli atcc 25922 - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

95
ATCC s typhimurium atcc 700408 multi resistant
Comparison between the decontamination effectiveness of UVC LEDs and chemical methods.
S Typhimurium Atcc 700408 Multi Resistant, supplied by ATCC, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/activity+against+multi+drug+resistant+e+coli+strain+atcc+baa/Salmonella+enterica%3B+subsp%2E+enterica%3B+serovar+Typhimurium/us08686113-639-61-63
Average 95 stars, based on 1 article reviews
s typhimurium atcc 700408 multi resistant - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

Image Search Results


Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) E. coli and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).

Journal: Advanced science (Weinheim, Baden-Wurttemberg, Germany)

Article Title: Droplet-Based Single-Cell Measurements of 16S rRNA Enable Integrated Bacteria Identification and Pheno-Molecular Antimicrobial Susceptibility Testing from Clinical Samples in 30 min.

doi: 10.1002/advs.202003419

Figure Lengend Snippet: Figure 2. PNA probe hybridization assay for specific detection of uropathogens. A) We have designed PNA probes specific to the i) E. coli and ii) P. mirabilis species, the iii) Enterobacterales order, and the iv) eubacterial kingdom, in order to be able to detect all predominant uropathogens. We ensure that the designed probes can detect signal from target bacteria over blank urine background (N) by measuring probe fluorescence in the presence of E. coli (EC), P. mirabilis (PM), K. pneumoniae (KP), and P. aeruginosa (PA) (p-values are calculated using unpaired one-tailed t-tests; *p < 0.05, **p < 0.01, ***p < 0.001, no asterisks between bars indicates no significant difference). B) Our assay works across a wide range of i) lysis temperatures and ii) hybridization temperatures (green: selected temperatures). C) Bulk-based pheno-molecular AST of reference E. coli ATCC 25922 and multi-drug resistant E. coli BAA 2471 using hybridization detection of 16S rRNA is feasible, but requires >90 min of culture/antibiotic exposure to differentiate the effect of gentamicin on the susceptible and the resistant strains of E. coli. Data presented as mean +/−SD, n ≥3 or n ≥2 (bulk pheno-molecular AST).

Article Snippet: To demonstrate, we incubated EC PNA probes with either multi-drug resistant E. coli ATCC BAA 2471 or the reference E. coli strain, each strain without and with gentamicin (at a bactericidal concentration of 8 μg mL−1) in 20 μL sample volume for 0, 60, 90, or 120 min at 37°C before subjecting these samples to 2 min 95 °C lysis, 30 min 60 °C hybridization, and LIF detection within 10 μm wide detection channels.

Techniques: Hybridization, Bacteria, One-tailed Test, Lysis

Figure 3. Single-cell detection of bacterial 16S rRNA from urine using microfluidic droplets. A) i) Urine samples of distinctly different color and turbidity can be discretized using flow-focusing to generate monodisperse droplets (scale bars ≈50 µm) of ii) 4 ± 1 pL volume. B) Droplet fluorescence peak traces i) without E. coli, droplets emit baseline fluorescence signal, and have a positive droplet rate of 0.0079% (also known as the average limit of blank). ii) In the presence of 107 CFU mL−1E. coli, droplets emit a higher fluorescence signal, and have a positive droplet rate of 6.67%. C) Droplet-based quantification of E. coli in urine across four orders of magnitude within the clinically relevant dynamic range for UTIs (104 to 2 × 107 CFU mL−1), R2

Journal: Advanced science (Weinheim, Baden-Wurttemberg, Germany)

Article Title: Droplet-Based Single-Cell Measurements of 16S rRNA Enable Integrated Bacteria Identification and Pheno-Molecular Antimicrobial Susceptibility Testing from Clinical Samples in 30 min.

doi: 10.1002/advs.202003419

Figure Lengend Snippet: Figure 3. Single-cell detection of bacterial 16S rRNA from urine using microfluidic droplets. A) i) Urine samples of distinctly different color and turbidity can be discretized using flow-focusing to generate monodisperse droplets (scale bars ≈50 µm) of ii) 4 ± 1 pL volume. B) Droplet fluorescence peak traces i) without E. coli, droplets emit baseline fluorescence signal, and have a positive droplet rate of 0.0079% (also known as the average limit of blank). ii) In the presence of 107 CFU mL−1E. coli, droplets emit a higher fluorescence signal, and have a positive droplet rate of 6.67%. C) Droplet-based quantification of E. coli in urine across four orders of magnitude within the clinically relevant dynamic range for UTIs (104 to 2 × 107 CFU mL−1), R2

Article Snippet: To demonstrate, we incubated EC PNA probes with either multi-drug resistant E. coli ATCC BAA 2471 or the reference E. coli strain, each strain without and with gentamicin (at a bactericidal concentration of 8 μg mL−1) in 20 μL sample volume for 0, 60, 90, or 120 min at 37°C before subjecting these samples to 2 min 95 °C lysis, 30 min 60 °C hybridization, and LIF detection within 10 μm wide detection channels.

Techniques:

Figure 4. Accelerating antimicrobial susceptibility assessment via quantitative measurement of 16S rRNA from single cells. A) LIF detection of droplets containing E. coli cells suspended in MH broth i) without 30 min culture results in the expected 8% positive droplet frequency (7.02% observed), ii) following 30 min culture results in higher positive droplet intensities (indicative of higher 16S rRNA production) and 7.70% frequency, and iii) and after 30 min culture along with bactericidal gentamicin results in lower positive droplet intensities (indicative of relatively lower 16S rRNA production) and 3.12% frequency. B) Resistant E. coli can be differentiated from reference E. coli spiked into urine by comparing the positive droplet percentage from cells subject to antibiotic and no-antibiotic conditions (“Normalized Positive Droplet Population”) for culture/drug exposure durations as low as 10 min. C) Resistant and susceptible strains of E. coli can be differentiated using our platform for three different antibiotics spanning distinct classes—gentamicin (aminoglycoside), ciprofloxacin (fluoroquinolone), and ampicillin (beta lactam). Error bars represent 1 standard deviation. The p-values are calculated from unpaired one-tailed t-tests.

Journal: Advanced science (Weinheim, Baden-Wurttemberg, Germany)

Article Title: Droplet-Based Single-Cell Measurements of 16S rRNA Enable Integrated Bacteria Identification and Pheno-Molecular Antimicrobial Susceptibility Testing from Clinical Samples in 30 min.

doi: 10.1002/advs.202003419

Figure Lengend Snippet: Figure 4. Accelerating antimicrobial susceptibility assessment via quantitative measurement of 16S rRNA from single cells. A) LIF detection of droplets containing E. coli cells suspended in MH broth i) without 30 min culture results in the expected 8% positive droplet frequency (7.02% observed), ii) following 30 min culture results in higher positive droplet intensities (indicative of higher 16S rRNA production) and 7.70% frequency, and iii) and after 30 min culture along with bactericidal gentamicin results in lower positive droplet intensities (indicative of relatively lower 16S rRNA production) and 3.12% frequency. B) Resistant E. coli can be differentiated from reference E. coli spiked into urine by comparing the positive droplet percentage from cells subject to antibiotic and no-antibiotic conditions (“Normalized Positive Droplet Population”) for culture/drug exposure durations as low as 10 min. C) Resistant and susceptible strains of E. coli can be differentiated using our platform for three different antibiotics spanning distinct classes—gentamicin (aminoglycoside), ciprofloxacin (fluoroquinolone), and ampicillin (beta lactam). Error bars represent 1 standard deviation. The p-values are calculated from unpaired one-tailed t-tests.

Article Snippet: To demonstrate, we incubated EC PNA probes with either multi-drug resistant E. coli ATCC BAA 2471 or the reference E. coli strain, each strain without and with gentamicin (at a bactericidal concentration of 8 μg mL−1) in 20 μL sample volume for 0, 60, 90, or 120 min at 37°C before subjecting these samples to 2 min 95 °C lysis, 30 min 60 °C hybridization, and LIF detection within 10 μm wide detection channels.

Techniques: Standard Deviation, One-tailed Test

Figure 5. DropDx clinical comparison study of 50 deidentified patient samples from Johns Hopkins Hospital. A) Each sample was simultaneously tested using clinical standard ID/AST tests as well as with 2 DropDx devices for measurements without and with ciprofloxacin. For ID, we used a combination of EC, EB, and UNI probes. B) Our 7-outcome DropDx workflow is used to determine if there is a Gram-negative bacterial infection present, whether the infecting pathogen is E. coli, whether the infecting pathogen is in the Enterobacterales order, or whether the infecting pathogen is a different (Gram- negative) bacteria and to assess the susceptibility of the infecting pathogen to ciprofloxacin. 𝜆is the proportion of droplets that contain a single cell to all droplets. C) Unbiased thresholding for each diagnostic metric was conducted in pilot studies using ROC curve analysis, and the final data groups and resulting ROC curves are plotted for i) differentiating culture-positive from culture-negative samples (AUC: 0.964), for ii) differentiating E. coli from non-E. coli samples (AUC: 1.000), for iii) differentiating Enterobacterales from non-Enterobacterales samples (AUC: 0.956), and for D) differentiating ciprofloxacin resistant from susceptible samples (AUC: 0.951). Importantly, DropDx’s single-cell pheno-molecular AST results in a categorical agreement of 95.3% with no major errors. Error bars represent mean and standard error. The p-values are calculated from unpaired one-tailed t-tests.

Journal: Advanced science (Weinheim, Baden-Wurttemberg, Germany)

Article Title: Droplet-Based Single-Cell Measurements of 16S rRNA Enable Integrated Bacteria Identification and Pheno-Molecular Antimicrobial Susceptibility Testing from Clinical Samples in 30 min.

doi: 10.1002/advs.202003419

Figure Lengend Snippet: Figure 5. DropDx clinical comparison study of 50 deidentified patient samples from Johns Hopkins Hospital. A) Each sample was simultaneously tested using clinical standard ID/AST tests as well as with 2 DropDx devices for measurements without and with ciprofloxacin. For ID, we used a combination of EC, EB, and UNI probes. B) Our 7-outcome DropDx workflow is used to determine if there is a Gram-negative bacterial infection present, whether the infecting pathogen is E. coli, whether the infecting pathogen is in the Enterobacterales order, or whether the infecting pathogen is a different (Gram- negative) bacteria and to assess the susceptibility of the infecting pathogen to ciprofloxacin. 𝜆is the proportion of droplets that contain a single cell to all droplets. C) Unbiased thresholding for each diagnostic metric was conducted in pilot studies using ROC curve analysis, and the final data groups and resulting ROC curves are plotted for i) differentiating culture-positive from culture-negative samples (AUC: 0.964), for ii) differentiating E. coli from non-E. coli samples (AUC: 1.000), for iii) differentiating Enterobacterales from non-Enterobacterales samples (AUC: 0.956), and for D) differentiating ciprofloxacin resistant from susceptible samples (AUC: 0.951). Importantly, DropDx’s single-cell pheno-molecular AST results in a categorical agreement of 95.3% with no major errors. Error bars represent mean and standard error. The p-values are calculated from unpaired one-tailed t-tests.

Article Snippet: To demonstrate, we incubated EC PNA probes with either multi-drug resistant E. coli ATCC BAA 2471 or the reference E. coli strain, each strain without and with gentamicin (at a bactericidal concentration of 8 μg mL−1) in 20 μL sample volume for 0, 60, 90, or 120 min at 37°C before subjecting these samples to 2 min 95 °C lysis, 30 min 60 °C hybridization, and LIF detection within 10 μm wide detection channels.

Techniques: Comparison, Infection, Bacteria, Diagnostic Assay, One-tailed Test

Comparison between the decontamination effectiveness of UVC LEDs and chemical methods.

Journal: Materials

Article Title: A Comprehensive Analysis of the UVC LEDs’ Applications and Decontamination Capability

doi: 10.3390/ma15082854

Figure Lengend Snippet: Comparison between the decontamination effectiveness of UVC LEDs and chemical methods.

Article Snippet: Methicillin-resistant S. aureus (ATCC 43000), multi-drug resistant K. pneumoniae (clinically isolated) , multi-drug-resistant E. faecium (ATCC 51559) , canine skin, muscle tissues , na , na , 270 , na , 15, 30, 40 , Yes (0.05% chlorhexidine) , “The bactericidal activity (...) in skin for S. aureus and K. pneumonia , but not E. faecium ” (UVC, p.1) AND “synergy against E. faecium when evaluated on skin.” (0.05% chlorhexidine/UVC, p.1) , Health , [ ] .

Techniques: Comparison, Bacteria